Fault phenomenon

cause

Method of exclusion

Inefficient

1. The traffic is too small
2. The gap between the two sides of the roller is not the same
3. The spring is crushed
4. Brush can not brush Luo Di
5. Not enough speed

1. Increase traffic
2. Adjust the lever inside the nut to make the gap consistent
3. Adjust the nut outside the lever so that the pressure of the universal spring is flat, not too deep
4. Adjust the brush position
5. Increase the pulley diameter

Shaft heating

1. The collar does not turn
2. High speed
3 bearing lack of oil

1. Open the bearing and remove dirt
2. Reduce engine speed
3. Refuel 1 or 2 times a day to keep enough lubricant

Flour is thick and not white

1. Screen coarse
2. Small roller gap
3. The hardness of the roller is low
4. The spring pressure is too large

1. Replace the fine screen
2. Increase the gap, release the big round
3. Change the roller
4. Adjust the outside of the lever to loosen the spring outwards