Model NO.: HYZ-100C 100mA
Frequency: 50Hz ± 0.5Hz
Time: 0.04~6.3s,23 Grades Together
Model: Xd4~2.9/100
Focus: Small Focus 1.8mm Big Focus4.3mm
Certificate: CE ISO
Trademark: Healicom
Transport Package: Carton
Specification: CE, ISO
Origin: Jiangsu, China
HS Code: 9018909090
Model NO.: HYZ-100C 100mA
Frequency: 50Hz ± 0.5Hz
Time: 0.04~6.3s,23 Grades Together
Model: Xd4~2.9/100
Focus: Small Focus 1.8mm Big Focus4.3mm
Certificate: CE ISO
Trademark: Healicom
Transport Package: Carton
Specification: CE, ISO
Origin: Jiangsu, China
HS Code: 9018909090
Medical Instrument Diagnostic X-ray Radioography Machine (Hyz-100c)
USE:

General Photography
Filter-ray device photography
 
FEATURES:
1. Single bed and single bulb.
2. Design according to the electric mechanism of middle-size machine. The function is full and reasonable.
3. The high-tension system is of march-past structure. Equipped with a full wave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation.
4. Supply voltage V, roentgenoscopy, photography KV and stepless adjustable.
5. Equipped with the manostat for filament of X-ray tube and the space charge compensator as to ensure the stable and accurate output.
6. Equipped with the capacity limitation and protection circuit and Kv mA sinter lock limitation and protection.
7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly
8. Examining bed is of electric back rotation and is equipped with vibrating filter-ray device.
9. The photographic flat bed has a vibrating ray-filter.
10. The upright post has the bottom track only, which is easy while installation.
 
Main Specifications
ITEM CONTENT INDEX
Supply power Voltage Single phase 380V/220V ± 10%
Frequency 50Hz ± 0.5Hz
Capacity 10KVA
Inner Resistance 2Ω at 380Vl; 0.6Ω
Photograph Max. Dc output voltage 90KV 100KV
Max. Dc output current 100mA 125mA
voltage 50~90KV 50~100KV
current small focus 25mA and big focus 50, 75, 100, 125mA four grades together
time 0.04~6.3s,23 grades together
High Voltage Transformer Unit capacity 7KVA 8.4KVA
X-ray Tube model XD4~2.9/100
focus small focus 1.8mm big focus4.3mm
Photographic bed(YZ-III) Bed face(L*W*H) 1960mmX660X700mm
Ray-filter Grid density  N28
Focusing distance 100cm
Grid Ratio 8:1
Max size of cassette for photograph 356mmX432mm(14" * 17")
Pillar of X-ray source unit move lengthwise (along the bottom track) >1350mm
move transverse >360mm
move up and down (along upright post) 720-1800mm
         
 
MAX.CAPACITY OF PHOTOGRAY
Focus of X-ray tube photography mA Max. photography KV Max. allowable expose time
small focus 25mA 90KV 100KV 1.0s
big focus 50 mA 90KV 95KV 6.3s
75 mA 90KV 95KV 5s
100 mA 85KV 90KV 3.2s
125mA 85KV 1.0s
 
UNIT CONFIGURATION
Control Desk,
High-Voltage generator unit,
High voltage cable,
X-ray tube unit,
Examining bed,
Upright post,
Collimator
 
Options
Chest film stand
Manual Diagnostic Table Medical Instrument Diagnostic X-ray Radioography Machine (Hyz-100c)
USE:

General Photography
Filter-ray device photography
 
FEATURES:
1. Single bed and single bulb.
2. Design according to the electric mechanism of middle-size machine. The function is full and reasonable.
3. The high-tension system is of march-past structure. Equipped with a full wave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation.
4. Supply voltage V, roentgenoscopy, photography KV and stepless adjustable.
5. Equipped with the manostat for filament of X-ray tube and the space charge compensator as to ensure the stable and accurate output.
6. Equipped with the capacity limitation and protection circuit and Kv mA sinter lock limitation and protection.
7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly
8. Examining bed is of electric back rotation and is equipped with vibrating filter-ray device.
9. The photographic flat bed has a vibrating ray-filter.
10. The upright post has the bottom track only, which is easy while installation.
 
Main Specifications
ITEM CONTENT INDEX
Supply power Voltage Single phase 380V/220V ± 10%
Frequency 50Hz ± 0.5Hz
Capacity 10KVA
Inner Resistance 2Ω at 380Vl; 0.6Ω
Photograph Max. Dc output voltage 90KV 100KV
Max. Dc output current 100mA 125mA
voltage 50~90KV 50~100KV
current small focus 25mA and big focus 50, 75, 100, 125mA four grades together
time 0.04~6.3s,23 grades together
High Voltage Transformer Unit capacity 7KVA 8.4KVA
X-ray Tube model XD4~2.9/100
focus small focus 1.8mm big focus4.3mm
Photographic bed(YZ-III) Bed face(L*W*H) 1960mmX660X700mm
Ray-filter Grid density  N28
Focusing distance 100cm
Grid Ratio 8:1
Max size of cassette for photograph 356mmX432mm(14" * 17")
Pillar of X-ray source unit move lengthwise (along the bottom track) >1350mm
move transverse >360mm
move up and down (along upright post) 720-1800mm
         
 
MAX.CAPACITY OF PHOTOGRAY
Focus of X-ray tube photography mA Max. photography KV Max. allowable expose time
small focus 25mA 90KV 100KV 1.0s
big focus 50 mA 90KV 95KV 6.3s
75 mA 90KV 95KV 5s
100 mA 85KV 90KV 3.2s
125mA 85KV 1.0s
 
UNIT CONFIGURATION
Control Desk,
High-Voltage generator unit,
High voltage cable,
X-ray tube unit,
Examining bed,
Upright post,
Collimator
 